EpiOcular™ Human Cell Construct EIT

Topic: Serious eye damage/Eye irritation

Test Method Number:
TM2008-10 (EU)
Short Name of TM:
EpiOcular EIT
Year received:
2008
Responsible Organisation:
Protocol(s)/SOP(s):
164

Method Description

The EpiOcular™ Eye Irritation Test (EIT) consists of a reconstructed human cornea-like epithelium (RhCE) tissue construct, a non-keratinized multi-layered epithelium prepared from non-transformed, human-derived epidermal keratinocytes which show a cornea-like structure analogous to that found in in vivo. The test chemical is applied topically to a minimum of two RhCE tissue constructs. Following the exposure and post-treatment incubation periods, tissue viability is assessed by MTT assay.

Track Approval Status

  •  
    Submission
  •  
    Validation
  •  
    Peer-review
  •  
    Recommendation
  •  
    Regulatory acceptance/Standards
Step
Submission Show status
Validation Show status
Peer-review Show status
Recommendation Show status
Regulatory acceptance/Standards Show status